Features:
â— 800W hot air rework station with LCD display.
â— 3 set shortcut air volume/temperature to simplify operations.
â— Support temp lock, temp calibration.
◠Support ℃ and ℉ switchable.
â— Auto standby and sleep funtion, conserves energy and protect equipment.
â— Password-protected function to preserve settings.
â— With 10~900s timing function.
â— Cold air function to cool components.
â— Cooling automatic function(standby), effectively protects the life span of heating core and handle.
♦ Easy Temperature/Air Flow Setting
1. Adjust the air flow value by AIR knob, “” “” / “”-“” to increase/reduce the air volume.
2. Adjust the temperature value by pressing “â–²” or “â–¼”, long press can be quickly adjusted.
♦ Saving and Call Shortcut Temperature
Press button “1”/ “2”/ “3” to call or save preset temperature and air flow value.
♦ Timing function
Under the HT menu, press “â–²” and “â–¼” keys to adjust the timing function working time. The setting time is 10 – 900 seconds.
♦ Standby Function
The hot air gun stand-by function can adjust in menu, “—” means standby. The hot air gun blows at the maximum air volume when the handle is placed on the holder, then enter stand-by status when the temperature drops under 100 ° C or stop heating after 15 seconds. The machine will return to work when picking up the handle.
♦ Auto-sleep function
The hot air station will automatic enter the sleep status and display OFF after 30 minutes of no activity, and it won’t re-work when the handle dropped or picked up until press any button to awaken.
♦ Temperature Lock Function
Under Loc Menu, it can turn on/off temperature lock function by pressing “â–²” or “â–¼” key.
♦ ℃/℉ available
In menu C-F mode, it can switch temperature unit ℃/℉ by pressing “â–²” or “â–¼” key.
♦ Temperature Calibration
Under menu CAL mode, press “â–²”or“â–¼” key to adjust the value. Calibration range is -50℃~ 50℃(-90℉~90℉). Calibration value will be negative as actual-measured temperature is lower than setting temperature; Calibration value will be positive as actual-measured temperature is higher than setting temperature.
♦ Beeping function
Under menu BL mode, it can turn on/ off the beeping function by pressing “â–²” or “â–¼”key.
♦ Password Setting Function
In PSD menu, press “â–²” or “â–¼” to adjust password setting value, which can be set from 01 to 999. “00” means password function is off. Default no password for the first time entrance. (Note: Directly input 906 password to enter menu in case of forgot the password.)
♦ Fault alarm function
S-E: Sensor fault.
H-E:Heating element fault.
Power: 800W
Input Voltage: AC100V/110V/120V|220V/230V/240V(optional)
Temperature Range: 100-500°C
Display mode: LCD Display
Pump: Brushless fan
Air Flow Gradation: 120L/ min(MAX)
Noise: <52dB(A)
Product Attributes :
Specification
Weight | 1600 g |
---|---|
Dimensions | 16.7 × 14.2 × 14.8 cm |
Dimensions for |
Product |
Type |
Hot Air Station |
Maximum Temperature |
500C – 932F |
Power |
800W |
Input Voltage |
AC230V±10% |
Uom |
Each |